|  | A high-frequency magnetic field is generated by coil L in the oscillation  circuit. When a target approaches the magnetic field, an induction current  (eddy current) flows in the target due to electromagnetic induction. As the  target approaches the sensor, the induction current flow increases, which  causes the load on the oscillation circuit to increase. Then, oscillation  attenuates or stops. The sensor detects this change in the oscillation status  with the amplitude detecting circuit, and outputs a detection signal. |